PTFE Filter Membranes

PTFE Fluoropolymer Filters for High-Purity/Aggressive environments
Flontex PTFE membranes are used extensively in pharmaceutical, laboratory, medical & semi-conductor processing applications where ultra pure or highly aggressive fluids & gases need to be filtered using inert, non-clogging filter media.
Flontex PTFE membranes are self supporting so backing liners are not required. Being naturally hydrophobic Flontex is an excellent venting material & due to its non-stick quality, Flontex exhibits unrivalled filter cake release properties. As standard, Flontex PTFE membranes are supplied as punched discs, however, semi-finished material in roll or sheet form is available on request.
Availability of FLONTEX G-100 PTFE Membranes
| FLONTEX G-100 Filter Discs (Supplied in packs of 50) | |
|---|---|
| Type | Ø (mm) |
| G-104 | 37, 47, 50 |
| G-106 | 37, 47, 50 |
| G-108 | 47 |
| G-110 | 47 |
| G-115 | 47 |
- Note: Other diameters on request
- Paper discs are placed between PTFE membranes to ensure cleanliness
- Semi-finished slit-to-width rolls: max W250mm x L30m.
Specification & Properties of FLONTEX G-100 PTFE Membranes
| Property | Unit | TYPE | ||||
|---|---|---|---|---|---|---|
| G-104 | G-106 | G-108 | G-110 | G-115 | ||
| Functional Pore Size | microns | 5-6 | 4-5 | 3-4 | 1-2 | 1-2 |
| Air Flow 100cc/1.0 In.2/20oz (Gurley test) | sec. | 1.7 +/- 0.8 | 2.5 +/- 1.5 | 4-5 | 5-6 | 6.5 +/- 1.5 |
| Bubble Point (Ethanol) | psi | 0.6 +/- 0.2 | 0.8 +/- 0.2 | 1.0 +/- 0.2 | 1.2 +/- 0.2 | 1.2 +/- 0.2 |
| Water Flow Rate Through 1 ft.2 @ 13.5 psi | GPM | 75 +/- 15 | 55 +/- 10 | 40 +/- 10 | 25 +/- 5 | 20 +/- 5 |
| Water Initiation Pressure | psi | 2 +/- 0.5 | 3 +/- 0.5 | 4 +/- 0.5 | 6 +/- 0.5 | 6 +/- 0.5 |
| Elongation | % | 75 | 75 | 75 | 75 | 75 |
| Pore Volume | % | 55 | 50 | 45 | 40 | 40 |
| Thickness | m | 0.10 +/-0.01 | 0.15 +/-0.02 | 0.20 +/-0.05 | 0.25 +/-0.05 | 0.38 +/-0.05 |
Click here for printable version – PTFE Filter Membranes
The data listed falls within the normal range of product properties but they should not be used to establish specification limits nor used alone as the basis of design. Polyflon Technology Limited assumes no obligation or liability for any advice furnished by it or for results obtained with respect to these products. All such advice is provided gratis and the buyer assumes sole responsibility for the results obtained in reliance thereon.